Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bdtd.unoeste.br:8080/jspui/handle/jspui/1168
Tipo do documento: Dissertação
Título: Comparação entre o teste de meniscometria de tira e outros testes oftálmicos em cães com olhos normais e com ceratoconjuntivite seca
Título(s) alternativo(s): Comparison between the strip meniscometry test and other ophthalmic tests in dogs with normal eyes and with keratoconjunctivitis sicca
Autor: Nascimento, Felipe Franco 
Primeiro orientador: Andrade, Silvia Maria Caldeira Franco
Primeiro membro da banca: Cassu, Renata Navarro
Segundo membro da banca: Brandão, Claudia Valéria Seullner
Resumo: O objetivo do presente estudo foi correlacionar o teste de meniscometria de tira (TMT) com o teste lacrimal de Schirmer 1 (TLS-1), o teste de ruptura do filme lacrimal (TRFL) e o teste de lissamina verde (TLV), em cães com olhos normais e com ceratoconjuntivite seca (CCS). Foram avaliados 138 olhos de 69 cães, sendo 78 olhos olhos normais, e 60 olhos diagnosticados com CCS. Foi realizado primeiramente o exame padrão TLS-1 para alocar os cães no grupo normal ou grupo CCS, e ato contínuo TMT, TRFL e TLV . Os resultados em média e desvio padrão do grupo normal foram: TLS-1 23,68±4,25, TMT 9,43±1,59, TRFL 23,06±6,95 e TLV 7 olhos positivos e do grupo CCS foram: TLS 6,20±4,45, TMT 3,02±2,52; TRFL 11,62±4,53 e TLV 14 olhos positivos. Houve uma correlação positiva entre os testes de TMT com TLS e TRFL e negativa entre TMT e TLV, sendo observada correlação forte e positiva entre TMT e TLS (r=0,87, p<0,001), moderada entre TMT e TRFL (r=0,61, p<0,001) e muito baixa entre TMT e TLV (r=-0,17, p<0,001). Considerou-se melhor ponto de corte do TMT o valor 7,5 mm/5seg segundo a Curva ROC, demonstrando 100% de sensibilidade e 91,7 % de especificidade. O presente estudo forneceu os valores de TMT em olhos normais e com CCS na espécie canina, demonstrando alta sensibilidade e especificidade comparado ao TLS, com um significativo poder preditivo para diagnóstico de CCS, podendo vir a substituir futuramente o TLS.
Abstract: The objective of the present study was correlate the strip meniscometry test (SMT) with the Schirmer tear test 1 (STT-1), the tear film break up test (TBUT), and the lissamine green test (LGT) in dogs with normal eyes and with dry keratoconjunctivitis (KCS). Were evaluated 138 eyes from 69 dogs, including 78 normal eyes and 60 eyes diagnosed with KCS. The tests were performed in the following sequence: the STT-1 was used to allocate the dogs to the normal group or the KCS group, followed by the SMT, TBUT, and LGT. The results in means and standard deviations for the normal group were: 23.68±4.25 (STT-1), 9.43±1.59 (SMT), and 23.06±6.95 (TBUT); LGT 7 positive eyes; and for the KCS group were: 6.20±4.45 (STT-1), 3.02±2.52 (SMT), and 11.62±4.53 (TBUT); LGT 14 positive eyes. There was a positive correlation between the SMT and the STT-1 and TBUT, as well as a negative correlation between the SMT and LGT. The correlation was very high between the SMT and STT-1 (r=0.87, p<0.001), moderate between the SMT and TBUT (r=0.61, p<0.001) and very low between the SMT and LGT (r=-0.17, p<0.001). The cut-off considered for the SMT was 7.5 mm/5 sec according to the ROC curve, presenting a sensitivity of 100% and specificity of 91.7%. This study provided SMT values in normal and KCS eyes for dogs, revealing high sensitivity and specificity compared with the STT-1 and a good predictive power for the diagnosis of KCS, showing that in the future, the SMT could replace the STT-1.
Palavras-chave: ceratoconjuntivite seca, cães, meniscometria de tira, teste de Schirmer, teste de ruptura do filme lacrimal, teste de lissamina verde.
dogs, keratoconjunctivitis sicca, lissamine green test, Schirmer tear test, strip meniscometry test, tear film breakup test.
Área(s) do CNPq: CIENCIAS AGRARIAS::MEDICINA VETERINARIA
Idioma: por
País: Brasil
Instituição: Universidade do Oeste Paulista
Sigla da instituição: UNOESTE
Departamento: Mestrado em Ciência Animal
Programa: Mestrado em Ciência Animal
Citação: Nascimento, Felipe Franco. Comparação entre o teste de meniscometria de tira e outros testes oftálmicos em cães com olhos normais e com ceratoconjuntivite seca. 2019. 31f. Dissertação (Mestrado em Ciência Animal) - Universidade do Oeste Paulista, Presidente Prudente, 2019.
Tipo de acesso: Acesso Aberto
URI: http://bdtd.unoeste.br:8080/jspui/handle/jspui/1168
Data de defesa: 4-Abr-2019