Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bdtd.unoeste.br:8080/jspui/handle/jspui/1231
Registro completo de metadados
Campo DCValorIdioma
dc.creatorPassareli, João Victor Goulart Consoni-
dc.creator.Latteshttp://lattes.cnpq.br/1111867734231962por
dc.contributor.advisor1Andrade, Silvia Maria Caldeira Franco-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/1455954245374682por
dc.contributor.referee1Cassu, Renata Navarro-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/1930132389295889por
dc.contributor.referee2Andrade , Alexandre Lima de-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/6404176495306171por
dc.date.accessioned2020-03-10T19:16:36Z-
dc.date.issued2019-11-29-
dc.identifier.citationPassareli, João Victor Goulart Consoni. Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães. 2019. 37f. Dissertação (Mestrado em Ciência Animal) - Universidade do Oeste Paulista, Presidente Prudente, 2019.por
dc.identifier.urihttp://bdtd.unoeste.br:8080/jspui/handle/jspui/1231-
dc.description.resumoO objetivo deste estudo foi comparar a acurácia dos tonômetros Tonovet e Tonovet Plus (rebote), Tono-Pen Avia Vet (aplanação) e Kowa (aplanação Goldmann) em cães. Foram mensurados a pressão intraocular (PIO) em 154 olhos de 77 cães. Através de um estudo post-mortem correlacionando os valores da manometria versus tonometria e calculando o coeficiente de correlação (r2), um estudo in vivo comparando a PIO real (manometria) com os tonômetros e um estudo ambulatorial em olhos saudáveis, e em olhos com sinais de glaucoma e uveíte. Os resultados obtidos no estudo post-mortem dos valores de (r2) em ordem decrescente foram: Kowa (0,989), Tonovet Plus (0,984), Tonovet (0,981) e Tono-Pen (0,847). Os valores da PIO em mmHg no estudo in vivo foram: manômetro aneroide (16,8 ± 2,5,7), Tonovet (18,1 ± 2,9), Tonovet Plus (20,6 ± 2,3), Tono-Pen (17,1 ± 2,5) e Kowa (16,1 ± 1.7); ambulatorial sadios: Tonovet (16,8 ± 3,8), Tonovet Plus (19,2 ± 2,9), Tono-Pen (16,2 ± 2,4) e Kowa (15,0 ± 1,3); glaucoma: Tonovet (30,2 ± 3,5), Tonovet Plus (35,0 ± 6,1), Tono-Pen (29,5 ± 4,2) e Kowa (23,9 ± 5,0); e uveíte: Tonovet (14,2 ± 1,4), Tonovet Plus (17,6 ± 1,9), Tono-Pen (13,7 ± 2,1) e Kowa (12,6 ± 1,7). Conclui-se que houve uma forte correlação entre os valores da PIO com a manometria em todos os tonômetros. Os valores mais altos de PIO foram com Tonovet Plus e os mais baixos com Kowa HA-2. Todos os tonômetros foram precisos na medição da PIO em cães, incluindo o mais recente, Tonovet Plus, que mostrou um excelente coeficiente de correlação.por
dc.description.abstractThe aim of this study was to compare the accuracy of Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation) and Kowa (Goldmann applanation) tonometers in dogs. Intraocular pressure (IOP) was measured in 130 eyes of 65 dogs. A post-mortem study was performed comparing manometry versus tonometry values and calculating the correlation coefficient (r2), an in vivo study comparing actual IOP (manometry) with tonometers and an outpatient study in healthy eyes and eyes with signs of glaucoma and uveitis. The results obtained in the postmortem study of (r2) values in decreasing order were: Kowa (0.989), Tonovet Plus (0.984), Tonovet (0.981) and Tono-Pen Avia Vet (0.847). The IOP values in mmHg in the in vivo study were: aneroid manometer (16.8 ± 2.5.7), Tonovet (18.1 ± 2.9), Tonovet Plus (20.6 ± 2.3), Tono Pen Avia Vet (17.1 ± 2.5) and Kowa (16.1 ± 1.7); healthy outpatients: Tonovet (16.8 ± 3.8), Tonovet Plus (19.2 ± 2.9), Tono-Pen Avia Vet (16.2 ± 2.4) and Kowa (15.0 ± 1.3); glaucoma: Tonovet (30.2 ± 3.5), Tonovet Plus (35.0 ± 6.1), Tono-Pen Avia Vet (29.5 ± 4.2) and Kowa (23.9 ± 5.0); and uveitis: Tonovet (14.2 ± 1.4), Tonovet Plus (17.6 ± 1.9), Tono-Pen Avia Vet (13.7 ± 2.1) and Kowa (12.6 ± 1.7). We can conclude that there was a strong correlation between IOP values and manometry in all tonometers. The highest values were with Tonovet Plus and the lowest with Kowa HA-2. All tonometers were accurate in measuring IOP in dogs, including the latest Tonovet Plus, which showed an excellent correlation coefficient.eng
dc.description.provenanceSubmitted by Michele Mologni (mologni@unoeste.br) on 2020-03-10T19:16:36Z No. of bitstreams: 1 João Victor Goulart Consoni Passareli.pdf: 1141173 bytes, checksum: bce2f7ba9618dc0f43f69b5e50cb8ac5 (MD5)eng
dc.description.provenanceMade available in DSpace on 2020-03-10T19:16:36Z (GMT). No. of bitstreams: 1 João Victor Goulart Consoni Passareli.pdf: 1141173 bytes, checksum: bce2f7ba9618dc0f43f69b5e50cb8ac5 (MD5) Previous issue date: 2019-11-29eng
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://bdtd.unoeste.br:8080/jspui/retrieve/3558/Jo%c3%a3o%20Victor%20Goulart%20Consoni%20Passareli.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade do Oeste Paulistapor
dc.publisher.departmentMestrado em Ciência Animalpor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNOESTEpor
dc.publisher.programMestrado em Ciência Animalpor
dc.rightsAcesso Abertopor
dc.subjectTonometria de aplanação, manometria direta, cães, tonometria de Goldmann, tonometria de rebote.por
dc.subjectApplanation tonometry, direct manometry, dogs, Goldmann tonometry rebound tonometry.eng
dc.subject.cnpqCIENCIAS AGRARIAS::MEDICINA VETERINARIApor
dc.titleComparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cãespor
dc.title.alternativeComparison between Tonovet, Tonovet Plus, Tono-Pen Avia Vet and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogseng
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado em Ciência Animal

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
João Victor Goulart Consoni Passareli.pdfJoão Victor Goulart Consoni Passareli1,11 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.