Exportar este item: EndNote BibTex

Use este identificador para citar ou linkar para este item: http://bdtd.unoeste.br:8080/jspui/handle/jspui/1222
Registro completo de metadados
Campo DCValorIdioma
dc.creatorJOÃO, Sheyla Adriane Rodrigues Oliveira.-
dc.creator.Latteshttp://lattes.cnpq.br/8639316518465777por
dc.contributor.advisor1Pizi, Eliane Cristina Gava-
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/2116665152731277por
dc.contributor.advisor-co1Matuda, Larissa Sgarbosa de Araujo-
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/3805942768534893por
dc.contributor.referee1Anderson, Catelan-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/4629404319391359por
dc.contributor.referee2Santos, Paulo Henrique dos-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/0493479801083622por
dc.date.accessioned2020-01-15T19:51:50Z-
dc.date.issued2019-02-25-
dc.identifier.citationJOÃO, Sheyla Adriane Rodrigues Oliveira. Influência da temperatura de volatilização do sistema adesivo na efetividade de restaurações em resina Bulk Fill - ensaio clínico randomizado. 2019. Dissertação (Mestrado em Odontologia) - Universidade do Oeste Paulista, Presidente Prudente, SP, 2019.por
dc.identifier.urihttp://bdtd.unoeste.br:8080/jspui/handle/jspui/1222-
dc.description.resumoObjetivos: Avaliar por meio deste estudo clínico randomizado duplo-cego, se houve influência de diferentes temperaturas de volatilização de um sistema adesivo universal em restaurações com resina composta Bulk Fill e também verificar se esta melhora permaneceu após 6 meses. Métodos: Foram selecionados 18 pacientes, com indicação de tratamento odontológico restaurador posterior bilateral. Assim cada paciente teve dois ou mais dentes restaurados com cavidade rasa sendo um de cada grupo, grupo Não Aquecido (GNA): condicionamento ácido prévio em esmalte por 30 segundos, volatilização do solvente presente no sistema adesivo (Single Bond Universal – 3M Espe –SBU) com jato de ar a 23°C por 05 segundos, seguido de restauração (Filtek Bulk Fill – 3M – Espe- RBF) e grupo Aquecido (GA): mesmos passos do grupo anterior, porém a volatilização do solvente presente no sistema adesivo foi realizada com jato de ar a 40°C por 05 segundos. Resultados: Para as propriedades estéticas, conforme os critérios de FDI, na avaliação de 15 dias os escores variaram entre 1 e 2, sendo que o maior percentual (67,6%) recebeu escore 1. Na avaliação de 6 meses, 5,4% das restaurações do GNA obtiveram escore 3 para o critério correspondência de cor e translucidez, e no GA todas as restaurações receberam escore 1 ou 2. Nenhuma restauração foi considerada como inaceitável sob este critério após 6 meses. Em relação as propriedades funcionais, as restaurações obtiveram escore 1 e 2 no período inicial. Após 6 meses, 1 (2,7%) restauração referente ao GNA, obteve escore 4 nos critérios: fratura do material/retenção e adaptação marginal, classificando-a como insatisfatória e necessitando de reparo. Para as propriedades biológicas na avaliação inicial, foram observadas duas (5,4%) restaurações, uma de cada grupo, com escore 3 para o critério de sensibilidade pós-operatória. Após 6 meses, 1 restauração obteve escore 4 para o mesmo critério. Houve uma melhora dos escores na avaliação de 6 meses.por
dc.description.abstractObjectives: To evaluate, by means of this double-blind randomized clinical study, if there was influence of different volatilization temperatures of a universal adhesive system on restorations with Bulk Fill composite resin and also to verify if this improvement remained after 6 months. Methods: We selected 18 patients, with indication of bilateral posterior restorative dental treatment. Thus, each patient had two or more restored teeth with shallow cavity being one of each group, Unheated group (GNA): previous acid conditioning in enamel for 30 seconds, solvent volatilization present in the adhesive system (Single Bond Universal - 3M Espe -SBU ) with air jet at 23 ° C for 05 seconds, followed by Filtek Bulk Fill (3M-Espe-RBF) and Heated group (GA): same steps from the previous group, however the solvent volatilization present in the adhesive system was performed with air jet at 40 ° C for 05 seconds. Results: For the aesthetic properties, according to FDI criteria, in the 15-day evaluation the scores ranged from 1 to 2, and the highest percentage (67.6%) received score 1. In the 6-month evaluation, 5.4 % of GNA restorations scored 3 for color matching and translucency, and in GA all restorations received score 1 or 2. No restoration was considered unacceptable under this criterion after 6 months. Regarding the functional properties, the restorations obtained score 1 and 2 in the initial period. After 6 months, 1 (2.7%) restoration related to GNA, obtained score 4 in the criteria: material fracture / retention and marginal adaptation, classifying it as unsatisfactory and in need of repair. For the biological properties in the initial evaluation, two (5.4%) restorations were observed, one in each group, with a score 3 for the postoperative sensitivity criterion. After 6 months, 1 restoration scored 4 for the same criteria. There was an improvement of the scores in the evaluation of 6 months.eng
dc.description.provenanceSubmitted by Jakeline Ortega (jakortega@unoeste.br) on 2020-01-15T19:51:50Z No. of bitstreams: 2 Sheyla Adriane Rodrigues Oliveira João.pdf: 1194878 bytes, checksum: da889a1d18a82ab9c82671e541dd789b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)eng
dc.description.provenanceMade available in DSpace on 2020-01-15T19:51:50Z (GMT). No. of bitstreams: 2 Sheyla Adriane Rodrigues Oliveira João.pdf: 1194878 bytes, checksum: da889a1d18a82ab9c82671e541dd789b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2019-02-25eng
dc.formatapplication/pdf*
dc.thumbnail.urlhttp://bdtd.unoeste.br:8080/jspui/retrieve/3507/Sheyla%20Adriane%20Rodrigues%20Oliveira%20Jo%c3%a3o.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade do Oeste Paulistapor
dc.publisher.departmentMestrado em Odontologiapor
dc.publisher.countryBrasilpor
dc.publisher.initialsUNOESTEpor
dc.publisher.programMestrado em Odontologiapor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectAdesivospor
dc.subjectRestauração Dentária Permanentepor
dc.subjectVolatilizaçãopor
dc.subjectAdhesiveeng
dc.subjectPermanent Dental Restorationeng
dc.subjectVolatilizationeng
dc.subject.cnpqCIENCIAS DA SAUDE::ODONTOLOGIApor
dc.titleInfluência da temperatura de volatilização do sistema adesivo na efetividade de restaurações em resina Bulk Fill - ensaio clínico randomizadopor
dc.title.alternativeInfluence Of Volatilization Temperature Of The Adhesive System In The Effectiveness of Bulk Fill resin results - randomized clinical assayeng
dc.typeDissertaçãopor
Aparece nas coleções:Mestrado em Odontologia

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Sheyla Adriane Rodrigues Oliveira João.pdfDocumento principal.1,17 MBAdobe PDFThumbnail

Baixar/Abrir Pré-Visualizar


Este item está licenciada sob uma Licença Creative Commons Creative Commons